# hinv -mv Location: /hw/module/001c01/node IP53_4CPU Board: barcode MXM746 part 030-1868-001 rev -C Location: /hw/module/001c01/IXbrick/xtalk/15 2U_INT_53 Board: barcode MTZ549 part 030-1809-003 rev -B Location: /hw/module/001c01/IXbrick/xtalk/15/pci-x/0/1/ioc4 IO9 Board: barcode MTS559 part 030-1771-005 rev -A Location: /hw/module/001c02/node IP53_4CPU Board: barcode MTA291 part 030-1868-001 rev -C Location: /hw/module/001c02/IXbrick/xtalk/15 2U_INT_53 Board: barcode MTV599 part 030-1809-003 rev -A 8 700 MHZ IP35 Processors CPU: MIPS R16000 Processor Chip Revision: 2.1 FPU: MIPS R16010 Floating Point Chip Revision: 2.1 CPU 0 at Module 001c01/Slot 0/Slice A: 700 Mhz MIPS R16000 Processor Chip (enabled) Processor revision: 2.1. Scache: Size 4 MB Speed 350 Mhz Tap 0xc CPU 1 at Module 001c01/Slot 0/Slice B: 700 Mhz MIPS R16000 Processor Chip (enabled) Processor revision: 2.1. Scache: Size 4 MB Speed 350 Mhz Tap 0xc CPU 2 at Module 001c01/Slot 0/Slice C: 700 Mhz MIPS R16000 Processor Chip (enabled) Processor revision: 2.1. Scache: Size 4 MB Speed 350 Mhz Tap 0xc CPU 3 at Module 001c01/Slot 0/Slice D: 700 Mhz MIPS R16000 Processor Chip (enabled) Processor revision: 2.1. Scache: Size 4 MB Speed 350 Mhz Tap 0xc CPU 4 at Module 001c02/Slot 0/Slice A: 700 Mhz MIPS R16000 Processor Chip (enabled) Processor revision: 2.1. Scache: Size 4 MB Speed 350 Mhz Tap 0xc CPU 5 at Module 001c02/Slot 0/Slice B: 700 Mhz MIPS R16000 Processor Chip (enabled) Processor revision: 2.1. Scache: Size 4 MB Speed 350 Mhz Tap 0xc CPU 6 at Module 001c02/Slot 0/Slice C: 700 Mhz MIPS R16000 Processor Chip (enabled) Processor revision: 2.1. Scache: Size 4 MB Speed 350 Mhz Tap 0xc CPU 7 at Module 001c02/Slot 0/Slice D: 700 Mhz MIPS R16000 Processor Chip (enabled) Processor revision: 2.1. Scache: Size 4 MB Speed 350 Mhz Tap 0xc Main memory size: 16384 Mbytes Instruction cache size: 32 Kbytes Data cache size: 32 Kbytes Secondary unified instruction/data cache size: 4 Mbytes Memory at Module 001c01/Slot 0: 8192 MB (enabled) Bank 0 contains 1024 MB (Premium) DIMMS (enabled) Bank 1 contains 1024 MB (Premium) DIMMS (enabled) Bank 2 contains 1024 MB (Premium) DIMMS (enabled) Bank 3 contains 1024 MB (Premium) DIMMS (enabled) Bank 4 contains 1024 MB (Premium) DIMMS (enabled) Bank 5 contains 1024 MB (Premium) DIMMS (enabled) Bank 6 contains 1024 MB (Premium) DIMMS (enabled) Bank 7 contains 1024 MB (Premium) DIMMS (enabled) Memory at Module 001c02/Slot 0: 8192 MB (enabled) Bank 0 contains 1024 MB (Premium) DIMMS (enabled) Bank 1 contains 1024 MB (Premium) DIMMS (enabled) Bank 2 contains 1024 MB (Premium) DIMMS (enabled) Bank 3 contains 1024 MB (Premium) DIMMS (enabled) Bank 4 contains 1024 MB (Premium) DIMMS (enabled) Bank 5 contains 1024 MB (Premium) DIMMS (enabled) Bank 6 contains 1024 MB (Premium) DIMMS (enabled) Bank 7 contains 1024 MB (Premium) DIMMS (enabled) Integral SCSI controller 5: Version SAS/SATA LS1064 Disk drive: unit 1 on SCSI controller 5 (unit 1) (XVM Local Disk) (primary path) Disk drive: unit 2 on SCSI controller 5 (unit 2) (XVM Local Disk) (primary path) Integral SCSI controller 6: Version Fibre Channel QL2342 Port 1, 100 MHz PCI-X Integral SCSI controller 2: Version IDE (ATA/ATAPI) IOC4 CDROM: unit 0 on SCSI controller 2 Integral SCSI controller 0: Version QL12160, low voltage differential Disk drive: unit 1 on SCSI controller 0 (unit 1) Integral SCSI controller 1: Version QL12160, low voltage differential Integral SCSI controller 3: Version LS1030, low voltage differential Integral SCSI controller 4: Version LS1030, low voltage differential Integral SCSI controller 7: Version Fibre Channel QL2342 Port 2, 100 MHz PCI-X IOC3/IOC4 serial port: tty3 IOC3/IOC4 serial port: tty4 IOC3/IOC4 serial port: tty5 IOC3/IOC4 serial port: tty6 Integral Gigabit Ethernet: tg0, module 001c01, PCI bus 1 slot 4 Gigabit Ethernet: tg1, module 001c01, PCI bus 2 slot 2 PCI Adapter ID (vendor 0x10a9, device 0x100a) PCI slot 1 PCI Adapter ID (vendor 0x1077, device 0x1216) PCI slot 3 PCI Adapter ID (vendor 0x14e4, device 0x1645) PCI slot 4 PCI Adapter ID (vendor 0x1000, device 0x0050) PCI slot 1 PCI Adapter ID (vendor 0x1077, device 0x2312) PCI slot 1 PCI Adapter ID (vendor 0x1077, device 0x2312) PCI slot 1 PCI Adapter ID (vendor 0x1000, device 0x0030) PCI slot 1 PCI Adapter ID (vendor 0x1000, device 0x0030) PCI slot 1 PCI Adapter ID (vendor 0x14e4, device 0x1645) PCI slot 2 IOC4 firmware revision 83 IOC3/IOC4 external interrupts: 1 HUB in Module 001c01/Slot 0: Revision 2 Speed 200.00 Mhz (enabled) HUB in Module 001c02/Slot 0: Revision 2 Speed 200.00 Mhz (enabled) IP35prom in Module 001c01/Slot n0: Revision 6.211 IP35prom in Module 001c02/Slot n0: Revision 6.211