# hinv -vm Location: /hw/module/001c04/node IP59_4CPU Board: barcode NSJ339 part 030-1989-003 rev -B Location: /hw/module/001c04/IXbrick/xtalk/15 2U_INT_53 Board: barcode NTX732 part 030-1809-006 rev -B Location: /hw/module/001c04/IXbrick/xtalk/15/pci-x/0/1/ioc4 IO9 Board: barcode NWD099 part 030-1771-005 rev -B 4 1.0 GHZ IP35 Processors CPU: MIPS R16000 Processor Chip Revision: 3.0 FPU: MIPS R16010 Floating Point Chip Revision: 3.0 CPU 0 at Module 001c04/Slot 0/Slice A: 1.0 Ghz MIPS R16000 Processor Chip (enabled) Processor revision: 3.0. Scache: Size 16 MB Speed 333 Mhz Tap 0x15 CPU 1 at Module 001c04/Slot 0/Slice B: 1.0 Ghz MIPS R16000 Processor Chip (enabled) Processor revision: 3.0. Scache: Size 16 MB Speed 333 Mhz Tap 0x15 CPU 2 at Module 001c04/Slot 0/Slice C: 1.0 Ghz MIPS R16000 Processor Chip (enabled) Processor revision: 3.0. Scache: Size 16 MB Speed 333 Mhz Tap 0x15 CPU 3 at Module 001c04/Slot 0/Slice D: 1.0 Ghz MIPS R16000 Processor Chip (enabled) Processor revision: 3.0. Scache: Size 16 MB Speed 333 Mhz Tap 0x15 Main memory size: 4096 Mbytes Instruction cache size: 32 Kbytes Data cache size: 32 Kbytes Secondary unified instruction/data cache size: 16 Mbytes Memory at Module 001c04/Slot 0: 4096 MB (enabled) Bank 0 contains 512 MB (Standard) DIMMS (enabled) Bank 1 contains 512 MB (Standard) DIMMS (enabled) Bank 2 contains 512 MB (Standard) DIMMS (enabled) Bank 3 contains 512 MB (Standard) DIMMS (enabled) Bank 4 contains 512 MB (Standard) DIMMS (enabled) Bank 5 contains 512 MB (Standard) DIMMS (enabled) Bank 6 contains 512 MB (Standard) DIMMS (enabled) Bank 7 contains 512 MB (Standard) DIMMS (enabled) Integral SCSI controller 2: Version IDE (ATA/ATAPI) IOC4 Integral SCSI controller 0: Version QL12160, low voltage differential Disk drive: unit 1 on SCSI controller 0 (unit 1) Disk drive: unit 2 on SCSI controller 0 (unit 2) Integral SCSI controller 1: Version QL12160, low voltage differential IOC3/IOC4 serial port: tty3 IOC3/IOC4 serial port: tty4 IOC3/IOC4 serial port: tty5 IOC3/IOC4 serial port: tty6 Integral Gigabit Ethernet: tg0, module 001c04, PCI bus 1 slot 4 10 Gigabit Ethernet: xg1, module 001c04, 100 MHz PCIX bus 2 slot 1 Gigabit Ethernet: tg1, module 001c04, PCI bus 2 slot 2 port 0 Gigabit Ethernet: tg2, module 001c04, PCI bus 2 slot 2 port 1 PCI Adapter ID (vendor 0x10a9, device 0x100a) PCI slot 1 PCI Adapter ID (vendor 0x1077, device 0x1216) PCI slot 3 PCI Adapter ID (vendor 0x14e4, device 0x1645) PCI slot 4 PCI Adapter ID (vendor 0x17d5, device 0x5831) PCI slot 1 PCI Adapter ID (vendor 0x14e4, device 0x1648) PCI slot 2 PCI Adapter ID (vendor 0x14e4, device 0x1648) PCI slot 2 IOC4 firmware revision 83 IOC3/IOC4 external interrupts: 1 HUB in Module 001c04/Slot 0: Revision 2 Speed 200.00 Mhz (enabled) IP35prom in Module 001c04/Slot n0: Revision 6.210